Metode Estimasi Suhu Minyak pada Transformator Tenaga melalui Pengukuran Suhu Body Berbasis IoT
Abstract
Oil cooled power transformer has important role in the electricity distribution system. Its windings were immersed in oil as an insulating medium and also as a cooler. This oil would be heated up due to several things, the most significant was heat generated by winding’s power loss. The monitoring of oil temperature on the transformer was always done routinely every day to maintain its performance and health condition. IoT based measurements could improved efficiency and minimized manpower resources. To realize this the indirect non-destructive measurement method was proposed to estimate transformator’s temperature oil. It will corellate the oil temperature and body temperature through a constant calibration factor derived from calculations. Conducted experiment applied to specific existing transformator and followed by calculations resulted a calibration factor = 1.7749. The smallest average of estimated temperature error was lied in the range of 40 - 90 degrees Celcius.
Downloads
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike International License (CC-BY-SA 4.0) that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
Copyright without Restrictions
The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
The submitted papers are assumed to contain no proprietary material unprotected by patent or patent application; responsibility for technical content and for protection of proprietary material rests solely with the author(s) and their organizations and is not the responsibility of the ULTIMA Computing or its Editorial Staff. The main (first/corresponding) author is responsible for ensuring that the article has been seen and approved by all the other authors. It is the responsibility of the author to obtain all necessary copyright release permissions for the use of any copyrighted materials in the manuscript prior to the submission.