Purwarupa Sistem Monitoring Kualitas Air pada Kolam Ikan Air Tawar
Abstract
In freshwater fish cultivation, the most important thing to guard and pay attention to is the quality of pond water for the survival of these fish. The resilience of the body of the fish is very dependent on the quality of the water, if the water quality is good then the resistance of the body of the fish to the attack of the disease will be better too. This research was conducted to design and build a prototype monitoring system for freshwater fish pond water quality that can provide information about the condition of freshwater fish ponds in real-time. This monitoring system is made using Arduino as a data processor and several sensors such as water pH sensors, water turbidity, and water temperature. Next is a web-based monitoring application. This system can be monitored directly by fish farmers via LCD screens and smartphones. Based on the test results, the temperature sensor has an offset value of 0.34, pH sensor 0.37, turbidity sensor 0.22 and the fish management monitoring system application can function properly.
Downloads
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike International License (CC-BY-SA 4.0) that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
Copyright without Restrictions
The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
The submitted papers are assumed to contain no proprietary material unprotected by patent or patent application; responsibility for technical content and for protection of proprietary material rests solely with the author(s) and their organizations and is not the responsibility of the ULTIMATICS or its Editorial Staff. The main (first/corresponding) author is responsible for ensuring that the article has been seen and approved by all the other authors. It is the responsibility of the author to obtain all necessary copyright release permissions for the use of any copyrighted materials in the manuscript prior to the submission.